Bismillah…
kemarin salah satu server kami (server HP Ml350 G5) tidak bisa booting setelah lama tidak di hidupkan , salah satu indikator led menyala dengan warna mearah berkedip (flashing) ,
berikut informasi HP ProLiant ML370 G5 Server – LEDs and Buttons
Systems Insight Display LEDs
To view a quick reference for component identification and status, access the Systems Insight Display.
Item
|
Description
|
Status
|
1
|
Primary power supply LED
|
Amber = Failure
Off = Normal
|
2
|
Redundant power supply LED
|
Amber = Failure
Off = Normal
|
3
|
Online spare memory LED
|
Green = Protection enabled
Amber = Memory failure occurred
Flashing amber = Memory configuration error
Off = No protection
|
4
|
Mirrored memory LED
|
Green = Protection enabled
Amber = Memory failure occurred
Flashing amber = Memory configuration error
Off = No protection
|
5
|
FBDIMM LEDs* (memory board 1)
|
Amber = Failure
Off = Normal
|
6
|
FBDIMM LEDs* (memory board 2)
|
Amber = Failure
Off = Normal
|
7
|
Processor 1 LED
|
Amber = Failure
Off = Normal
|
8
|
PPM 1 LED
|
Amber = Failure
Off = Normal
|
9
|
Processor 2 LED
|
Amber = Failure
Off = Normal
|
10
|
PPM 2 LED
|
Amber = Failure
Off = Normal
|
11
|
Hot-plug fan LEDs
|
Amber = Failure or fan is not installed
Off = Normal
|
12
|
Internal system health LED
|
Green = Normal (system on)
Amber = System health is degraded
Red = System health is critical
Off = Normal (system off)
|
13
|
External system health LED (power supply)
|
Green = Normal (system on)
Amber = Redundant power supply failure
Red = Power supply failure. No operational power supplies.
Off = Normal (system off)
|
14
|
Overtemperature LED
|
Red = Overheating, critical
Off = Normal
|
15
|
System power LED
|
Green = System has AC power and is powered on
Amber = System has AC power and is in standby mode
Off = System has no AC power
|
* If all FBDIMM LEDs for a memory board are flashing, the memory board is unseated.
nah untuk menangani nya , dari beberapa saran di forum HP ,
langkah pertama cabut baterai dari system board , langkah ke dua cabut memori board kemudian masukan lagi, langkah ke tiga masukan lagi baterai ke system board(mother board) terakhir coba boot lagi ,
dari saran di atas jika masih belum bisa boot dan led Internal system health masi menyala merah , di langkah ke dua setelah cabut memori board , cabut juga satu persatu memori nya kemudian pasang lagi dan coba boot ulang.
semoga bermanfaat 🙂
referensi:
https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/ML350-G5-won-t-boot-red-internal-health-LED-undocumented-system/td-p/4831011
http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00745284
No Comments, Be The First!