server HP ML350 G5 tidak bisa booting [red internal System health LED]

Bismillah…
kemarin salah satu server kami (server HP Ml350 G5) tidak bisa booting setelah lama tidak di hidupkan , salah satu indikator led menyala dengan warna mearah berkedip (flashing) ,

photo_2016-10-05_10-00-23

berikut informasi  HP ProLiant ML370 G5 Server – LEDs and Buttons

Systems Insight Display LEDs

To view a quick reference for component identification and status, access the Systems Insight Display.

Item
Description
Status
1
Primary power supply LED
Amber = Failure
Off = Normal
2
Redundant power supply LED
Amber = Failure
Off = Normal
3
Online spare memory LED
Green = Protection enabled
Amber = Memory failure occurred
Flashing amber = Memory configuration error
Off = No protection
4
Mirrored memory LED
Green = Protection enabled
Amber = Memory failure occurred
Flashing amber = Memory configuration error
Off = No protection
5
FBDIMM LEDs* (memory board 1)
Amber = Failure
Off = Normal
6
FBDIMM LEDs* (memory board 2)
Amber = Failure
Off = Normal
7
Processor 1 LED
Amber = Failure
Off = Normal
8
PPM 1 LED
Amber = Failure
Off = Normal
9
Processor 2 LED
Amber = Failure
Off = Normal
10
PPM 2 LED
Amber = Failure
Off = Normal
11
Hot-plug fan LEDs
Amber = Failure or fan is not installed
Off = Normal
12
Internal system health LED
Green = Normal (system on)
Amber = System health is degraded
Red = System health is critical
Off = Normal (system off)
13
External system health LED (power supply)
Green = Normal (system on)
Amber = Redundant power supply failure
Red = Power supply failure. No operational power supplies.
Off = Normal (system off)
14
Overtemperature LED
Red = Overheating, critical
Off = Normal
15
System power LED
Green = System has AC power and is powered on
Amber = System has AC power and is in standby mode
Off = System has no AC power

* If all FBDIMM LEDs for a memory board are flashing, the memory board is unseated.

 

nah untuk menangani nya , dari beberapa saran di forum HP ,

langkah pertama cabut  baterai dari system board , langkah ke dua cabut memori board kemudian masukan lagi, langkah ke tiga masukan lagi baterai ke system board(mother board)  terakhir  coba boot lagi ,

dari saran di atas jika masih belum bisa boot dan led Internal system health masi menyala merah , di langkah ke dua setelah cabut memori board , cabut juga satu persatu memori nya kemudian pasang lagi dan coba boot ulang.

semoga bermanfaat  🙂

referensi:

https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/ML350-G5-won-t-boot-red-internal-health-LED-undocumented-system/td-p/4831011

http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00745284

 

No Comments, Be The First!

Your email address will not be published.

Time limit is exhausted. Please reload CAPTCHA.